Description: NEW Server Tech PRO2 Switched POPS 3.3kW/7.3kW (24) C13 (6) C19) PDU SEV-6501GP/N: SEV-6501G Included 1 x NEW Server Tech PRO2 Switched POPS 3.3kW/7.3kW (24) C13 (6) C19) PDU SEV-6501G Overview The Server Technology PRO2 Switched POPS CDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS and POPS technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS "Master" CDU can be connected to as many as three PRO2 Switched POPS "Link" CDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration. Features Network Monitoring The PRO2 hot-swappable network card provides for HTTP(S), SSH, Telnet,SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.Hot-Swap Network Card Network access is ensured when power is lost to the Master unit with backup power provided by the primary link unit.Star Multi-Linking PRO2 provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.Temperature/ Humidity Monitoring PRO2 Master and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.Auto-Flip Current Display Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.Per-Inlet Power Sensing Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.Per-Outlet Power Sensing Meets ANSI C12.1 for billing-grade accuracy of Current per phase. POPS includes voltage, active power, apparent power, power factor, and energy.Branch Current Monitoring PRO2 monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.Branch Circuit Protection PRO2 meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.Outlet Control On PRO2 Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.High Retention Locking Outlets PRO2 receptacles have high retention and are compatible with P-Lock type power cords.High Temperature Rating This product has been tested and approved for safe and reliable operation in 60°C (140°F) data center environments.Power Pivot The 90 degree rotatable power cord allows for standardized deployment at any facility no matter where power must be routed.Flexible Mounting PRO2 includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details).Color Identification Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.Cisco EnergyWise Compliant PRO2 meets the requirements set forth by Cisco Systems, Inc. for its EnergyWise program for monitoring of device energy. EnergyWise is a registered trademark of Cisco Systems, Inc. Specification Inputs Input Voltage (V): 208Input Plug: IEC C20 100-240V InletInput Current (A): 20Input Current Rated (A): 16Input Power Capacity (kW): 3.3Requires PTCORD-L1, -L2, -L3, -L4, -L5, -L6, or –L7Outputs Connector: (24) x IEC 60320/C13 : ≤ 10A @230V L-N(6) x IEC 60320/C19 : ≤ 16A @230V L-N Branch Circuit Protection UL489 Compliant 2-pole, 20A trip circuit breakers, two (2) branch, rating: ≤ 16A, 5 kAIC Interrupt RatingPhysical Dimensions: 69.0in tall x 2.2in wide x 2.25in deep [1753mm x 56mm x 58mm]Environmental Operating Environment: 32°F to 140°F / 0°C to 60°C | 8%RH to 90%RH non-condensing | 6,500ft/2km elevation Storage Environment: -40°F to 185°F / -40°C to 85°C | 8%RH to 90%RH non-condensing | 50,000ft/15km elevation Quiescent / Unloaded Power Draw: < 10W for all configurationsCommunications & Security 10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU}Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6,LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTPMeasurement Accuracy Input Measurement Accuracy: LED Current = ± 10% at 0.1 amp (0.3 - 9.9 amps) and 1 amp (> 9.9 amps) resolutionGUI Current = ± 1% at 0.01 amp resolution (above 0.25 amp)Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%)Active Power = ± 1% at 1 watt resolutionApparent Power = ± 1% at 1 volt-amp resolutionPower Factor = ± 3% at 0.01 resolutionCrest Factor = ± 10% at 0.1 resolutionEnergy = ± 1% at 0.1 kilowatt-hour resolutionOutput Measurement Accuracy GUI Current = ± 1% at 0.01 amp resolution (above 0.15 amp)Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%)Active Power = ± 1% at 1 watt resolutionApparent Power = ± 1% at 1 volt-amp resolutionPower Factor = ± 3% at 0.01 resolutionCrest Factor = ± 10% at 0.1 resolutionEnergy = ± 1% at 1 watt-hour resolutionBranch Measurement Accuracy Current = ± 3% at 0.01 amp resolution (above 0.5 amp) VAT @ 20% INCLUDED IN PRICE - VAT INVOICE PROVIDED £233.33 excluding VAT VAT IS NOT PAYABLE BY PURCHASERS OUTSIDE OF THE UKTH 217953 217954 217955 217956 217957 217958 217959
Price: 280 GBP
Location: North London
End Time: 2023-12-07T21:42:47.000Z
Shipping Cost: 0 GBP
Product Images
Item Specifics
Return postage will be paid by: Buyer
Returns Accepted: Returns Accepted
After receiving the item, your buyer should cancel the purchase within: 30 days
Brand: Server Technology
Voltage Compatibility: 208 V
Type: PDU
Not Included: Power Cable
Model: SEV-6501G
MPN: SEV-6501G
Cable Length: Not Applicable
Max. Input Current: 20A
Modified Item: No